Industrial Octiv Specifications

Measuring Parameters (Range)

Voltage Range Voltage 20 – 3000 Vrms
Current Range 0.1 – 20 Arms*
Phase Range ± 180º
Harmonic (Voltage, Current and Phase) Up to 15 Harmonics per frequency
Frequency Range 350 kHz - 300 MHz
Fundamental Frequencies 5 Simultaneous
Impedance 1 to 500 Ω
Power Real, Forward and Reflected (Watt) [Mono] 200 mW to 12 kW*
Power Real, Forward and Reflected (dBm) [Mono] 25 dBm to 70 dBm

*Connector dependent

Pulsed Parameters (Time)

Voltage Time 1 μs
Current Time 1 μs
Phase Time 1 μs
Harmonic (Voltage, Current and Phase) Time 1 μs
Frequency Time 1 μs
Impedance Time 1 μs
Power Real, Forward and Reflected (Watt) Time 1 μs
Power Real, Forward and Reflected (dBm) Time 1 μs

Measuring Parameters (Accuracy)

Voltage Accuracy ± 1%
Current Accuracy ± 1%
Phase Accuracy ± 1º
Harmonic (Voltage, Current and Phase) Accuracy ± 5%
Frequency Accuracy ± 10 kHz

Measuring Parameters (Resolution)

Voltage Resolution 0.25 V
Current Resolution 10 mA
Phase Resolution 0.01°
Harmonic (Voltage, Current and Phase) Resolution As Above
Frequency Resolution 1 kHz

Sensor

Dimensions 70mm x 107mm x 55 | Custom designs upon request
Number of fundamentals Maximum of 5 simultaneously
RF Power Max 12 kW (higher available with custom connector)
Operating Temperature 10°C - 80°C (50 to 176°F)
Storage Temperature -20 to +80°C (-4 to +176°F)
Harmonic Content Measured (No Limit within Range)
Connectors BNC-Female, BNC-Male, HN-Female, HN-Male, LC-Female, LC-Male, N-Female, N-Male, SMA-Female, SMA-Male, 7/16 Jack, IEC Type 169-4, 7/16 Plug, IEC Type 169-4, Mini UHF-Female, UHF-Female, UHF-Male, 1-5/8" EIA Fixed, 7/8" EIA, TNC-Female, TNC-Male, and Open Term. #10-32 Nut, (Custom available on request)
Sensor Impedance 50 Ω
Calibration Cycle 12 Months

Application Software (USB 2.0)

Operating System Windows 2000 / XP / Vista / Windows 7 / Windows 8 / Windows 10
Connectivity Ethernet Web Service Protocol*

*EtherNet/IP and EtherCAT available on request